DRVSPEED=BEST_EMI
EM01 Configurations
IPKVAL | EM01 Peak Current Setting 3 (Load36mA): Ipeak = 90mA, IL = 36mA 4 (Load40mA): Ipeak = 100mA, IL = 40mA 5 (Load44mA): Ipeak = 110mA, IL = 44mA 6 (Load48mA): Ipeak = 120mA, IL = 48mA 7 (Load52mA): Ipeak = 130mA, IL = 52mA 8 (Load56mA): Ipeak = 140mA, IL = 56mA 9 (Load60mA): Ipeak = 150mA, IL = 60mA |
DRVSPEED | EM01 Drive Speed Setting 0 (BEST_EMI): Lowest Efficiency, Lowest EMI… Small decrease in efficiency from default setting 1 (DEFAULT_SETTING): Default Efficiency, Acceptable EMI level 2 (INTERMEDIATE): Small increase in efficiency from the default setting 3 (BEST_EFFICIENCY): Highest Efficiency, Highest EMI… Small increase in efficiency from INTERMEDIATE setting |